Architectural Specification
Kelley FXTM Dockleveler
Section 11161 - Page 1
Docklevelers
Part 1 - General
1.01 - WORK INCLUDED
A. Factory assembled dockleveler to include all necessary controls.
B. Curb angles with anchors for casting into concrete.
C. Installation and Owner's Manual.
1.02 - RELATED WORK
A. Section 11160 - Trailer Restraints.
B. Section 11164 - Seals and Shelters.
C. Section 11165 - Dock Bumpers.
1.03 - REFERENCES
A. ANSI MH 14.1 1987 "Loading Docklevelers and Dock Boards."
1.04 - SYSTEM DESCRIPTION
A. Lug style hinged lip; air powered recessed dockleveler to the following
requirements:
1. NOMINAL SIZE:_________ feet wide and _________ feet long.
2. CAPACITY:__________ lbs. (Letter Rating not acceptable under
ANSI MH 14.1 1987 standard.)
3. SERVICE RANGE: __________ inches above dock level and
__________ inches below dock level.
4. Dockleveler lip to extend a minimum of 12 full inches beyond outside
face of dock bumpers for maximum available service to most standard
trailers with 16" Lip.
1.05 - SUBMITTALS
A. Manufacturer's Installation Instructions.
B. Submit pit prints showing pit dimensions, wiring diagrams, and roughing-in
dimension as well as any conduit runs if necessary.
Section 11161- Page 2
Docklevelers
Part 2 - Products
2.01 - ACCEPTABLE MANUFACTURERS
A. Model FXTM as manufactured by Kelley Dock Systems, Milwaukee, WI.
2.02 - EQUIPMENT
A. CURB ANGLES: Eight pieces, 3x3x3/16", to cover all exposed edges of
pit and forward dock edge as required for bumper mounting.
B. LEVELER:
1. RAMP: Reinforced with twist resistant lamda style cold-roll beams.
Torsionally compliant ramp construction to be three sided without header
plate. Four hinge pins at rear of ramp assembly. Lug hinges welded
directly to deck and beam front with a minimum of 15 1/2" of weld.
Open lug style lip hinge construction. Lip hinge to allow swept debris to
fall to ground between lip and hinge pin and deck and hinge pin. To
include structural full operating range toe guards with Safety Yellow
markings as required by OSHA as per ANSI - Z535.
2. LIP: Hinge pin lugs to be welded a minimum of 3" from rear edge of
lip towards front edge, or provide 4" of lip support under lip from
rear edge. Lip hinge welds to run parallel to deck reinforcement beams for
added strength.
3. SUB FRAME: 19" deep to facilitate 20", sloped and 24" deep pit
configurations. Rear portion equipped with four upright members that
form ramp rear hinges. Side of formed longitudinal angle members to
connect with rear portion of subframe and front dock leveler support
leg and ramp pads.
4. DOCK LEVEL SUPPORT: Two structural formed dock level
support legs at forward end of ramp to be designed to rest on subframe ramp support pads for increased positioning accuracy.
60,000 lb. structural dock level support legs - drop tested to the full
rated capacity of the leveler - provide free fall protection.
5. LIFTING SYSTEM: Ramp powered by low-pressure system,
driven by a two-stage 10 amp fan motor which directs air into bag
subassembly and lifts ramp and lip assembly. System to be activated
by push-button and include automatic lip extension.
6. ENVIRONMENT: Lifting system to be free from hydraulic fluids
which may potentially harm the environment and surrounding ground
water supplies.
Section 11161 - Page 3
Docklevelers
Part 2 - Products (Continued)
7. WARRANTIES: Lifting system to be warranted for five years
parts and labor, and include all fittings, seals, motor, and air bag.
All lifting system components to be free from defects in material and
workmanship for a period of five years from date of installation.
Lip
hinge to carry a lifetime parts and labor warranty. Dockleveler
structure (dock section, lip section, rear hinge, front hinge and
subframe) to carry a 10 year warranty.
8. LIP LIFTING SYSTEM: Gravity LipTM automatic lip extension
system to automatically extend lip. Lip extension to allow for leading
edge of lip to clear a point 12" inches above dock and 4" away from
dock face wall.
9. MOTOR AND CONTROLS: Air powered lifting system powered
by 10 amp, two-stage, 115v, 1 phase fan motor. Housing to be easy
access with re-usable and cleanable air filter. Controls to be shielded
NEMA 4 push-button operation.
10. NIGHT LOCKS: Night locks to be attached to ramp support
pads on subframe and not dependent on lip support to reduce stress
on lip hinge assembly.
11. FINISH: Structural ramp and subframe sections of unit to be shot
cleaned and painted with rust-inhibiting paint.
Part 3 - Execution
3.01 - PREPARATION
A. Provide curb angle for building into work (optional).
B. Pit Design:
1. 20" pit depth for new construction to reduce forming.
2. 20" to 24" sloped pit depth for food and food service
applications to facilitate easy pit clean out of debris and water.
3.02 - INSTALLATION
A. Install in flat or sloped prepared pit in accordance with manufacturers
installation instructions.
B. Set square and level; anchor securely flush to dock floor; shim where
applicable to keep flush; weld back and front of subframe to curb angles.
C. Adjust installed unit for operation as specified by manufacturer.