Architectural Specification

Kelley FXTM Dockleveler

 

Section 11161 - Page 1

 

Docklevelers

 

Part 1 - General

 

            1.01 - WORK INCLUDED

                        A. Factory assembled dockleveler to include all necessary controls.

                        B. Curb angles with anchors for casting into concrete.

                        C. Installation and Owner's Manual.

 

            1.02 - RELATED WORK

                        A. Section 11160 - Trailer Restraints.

                        B. Section 11164 - Seals and Shelters.

                        C. Section 11165 - Dock Bumpers.

 

            1.03 - REFERENCES

                        A. ANSI MH 14.1 1987 "Loading Docklevelers and Dock Boards."

 

            1.04 - SYSTEM DESCRIPTION

                        A.  Lug style hinged lip; air powered recessed dockleveler to the following

                              requirements:

                                    1. NOMINAL SIZE:_________ feet wide and _________ feet long.

                                    2. CAPACITY:__________ lbs. (Letter Rating not acceptable under

                                        ANSI MH 14.1 1987 standard.)

                                    3. SERVICE RANGE: __________ inches above dock level and

                                        __________ inches below dock level.

                                    4. Dockleveler lip to extend a minimum of 12 full inches beyond outside

                                        face of dock bumpers for maximum available service to most standard

                                        trailers with 16" Lip.

 

            1.05 - SUBMITTALS

                        A. Manufacturer's Installation Instructions.

                        B. Submit pit prints showing pit dimensions, wiring diagrams, and roughing-in

                            dimension as well as any conduit runs if necessary.


Section 11161- Page 2

 

Docklevelers

 

Part 2 - Products

 

            2.01 - ACCEPTABLE MANUFACTURERS

                        A. Model FXTM  as manufactured by Kelley Dock Systems, Milwaukee, WI.

 

            2.02 - EQUIPMENT

                        A. CURB ANGLES: Eight pieces, 3x3x3/16", to cover all exposed edges of

                             pit and forward dock edge as required for bumper mounting.

                        B. LEVELER:

                                    1. RAMP: Reinforced with twist resistant lamda style cold-roll beams.

                                    Torsionally compliant ramp construction to be three sided without header

                                    plate.  Four hinge pins at rear of ramp assembly.  Lug hinges welded

                                    directly to deck and beam front with a minimum of 15 1/2" of weld.

                                    Open lug style lip hinge construction.  Lip hinge to allow swept debris to

                                    fall to ground between lip and hinge pin and deck and hinge pin.  To

                                    include structural full operating range toe guards with Safety Yellow

                                    markings as required by OSHA as per ANSI - Z535.

                                    2. LIP: Hinge pin lugs to be welded a minimum of 3" from rear edge of

                                    lip towards front edge, or provide 4" of lip support under lip from

                                    rear edge.  Lip hinge welds to run parallel to deck reinforcement beams for

                                    added strength.

                                    3. SUB FRAME: 19" deep to facilitate 20", sloped and 24" deep pit

                                    configurations.  Rear portion equipped with four upright members that

                                    form ramp rear hinges.  Side of formed longitudinal angle members to

                                    connect with rear portion of subframe and front dock leveler support

                                    leg and ramp pads.

                                    4. DOCK LEVEL SUPPORT: Two structural formed dock level

                                    support legs at forward end of ramp to be designed to rest on                                                  subframe ramp support pads for increased positioning accuracy. 

                                    60,000 lb. structural dock level support legs - drop tested to the full

                                    rated capacity of the leveler - provide free fall protection. 

                                    5. LIFTING SYSTEM: Ramp powered by low-pressure system,

                                    driven by a two-stage 10 amp fan motor which directs air into bag

                                    subassembly and lifts ramp and lip assembly.  System to be activated

                                    by push-button and include automatic lip extension.

                                    6. ENVIRONMENT: Lifting system to be free from hydraulic fluids

                                    which may potentially harm the environment and surrounding ground

                                    water supplies.


Section 11161 - Page 3

 

Docklevelers

 

Part 2 - Products (Continued)

 

                                    7. WARRANTIES: Lifting system to be warranted for five years

                                    parts and labor, and include all fittings, seals, motor, and air bag.

                                    All lifting system components to be free from defects in material and

                                    workmanship for a period of five years from date of installation.  Lip

                                    hinge to carry a lifetime parts and labor warranty.  Dockleveler

                                    structure (dock section, lip section, rear hinge, front hinge and

                                    subframe) to carry a 10 year warranty.

                                    8. LIP LIFTING SYSTEM: Gravity LipTM automatic lip extension

                                    system to automatically extend lip.  Lip extension to allow for leading

                                    edge of lip to clear a point 12" inches above dock and 4" away from

                                    dock face wall.

                                    9. MOTOR AND CONTROLS: Air powered lifting system powered

                                    by 10 amp, two-stage, 115v, 1 phase fan motor.  Housing to be easy

                                    access with re-usable and cleanable air filter.  Controls to be shielded

                                    NEMA 4 push-button operation.

                                    10. NIGHT LOCKS: Night locks to be attached to ramp support

                                    pads on subframe and not dependent on lip support to reduce stress

                                    on lip hinge assembly.

                                    11. FINISH: Structural ramp and subframe sections of unit to be shot

                                    cleaned and painted with rust-inhibiting paint.

 

Part 3 - Execution

 

            3.01 - PREPARATION

                        A. Provide curb angle for building into work (optional).

                        B. Pit Design:

                                    1. 20" pit depth for new construction to reduce forming.

                                    2. 20" to 24" sloped pit depth for food and food service

                                        applications to facilitate easy pit clean out of debris and water.

 

            3.02 - INSTALLATION

                        A. Install in flat or sloped prepared pit in accordance with manufacturers

                             installation instructions.

                        B. Set square and level; anchor securely flush to dock floor; shim where

                             applicable to keep flush; weld back and front of subframe to curb angles.

                        C. Adjust installed unit for operation as specified by manufacturer.