SPACELOFT SPECIFICATION GUIDE
Use this sample to prepare your own detailed specifications.
Provided as a representative sample, the following is based on many of
the standard design principles of SpaceLoft Mezzanines. For further
assistance, contact us.
I. GENERAL
- Mezzanine shall be prefabricated custom-designed unit
such as the SpaceLoftTM
manufactured by W.A. Schmidt, 38 Souderton Pk., Souderton, PA 18964.
- Mezzanine shall be free-standing and shall not use
existing walls or building columns for vertical or horizontal
support.
- Mezzanine structure shall be capable of being erected,
dismantled and relocated with hand tools.
- Mezzanine to be designed for add-on capability -
Columns and beams to have capacity and appropriate design to accept
add on units for future expansion.
- Bidder shall include the following information with
bid package -
- Design live load in pounds per square foot (psf)
- Deflection under the design live load.
- Maximum load on floor (psi) when design live load
is applied to baseplate.
- Height to top of deck and minimum clear height
below mezzanine.
- Shipping weight.
- The successful bidder after receipt of order shall
supply drawings by a qualified designer showing location of each
component, along with a material list, and connection details for
approval.
- Mezzanine manufacturer must verify experience in the
design and fabrication of mezzanines.
- Manufacturer shall offer certification of final
drawings by a Professional Engineer in the state in which
installation will occur and must be capable of providing
calculations and seal.
- Manufacturer to confirm that all factory welders are
certified.
II. DESIGN
- SPECIFICATIONS
- The structural steel design shall meet or exceed
the requirements of the American Institute of Steel Construction
(AISC) “Specification for Structural Steel Buildings/Allowable
Stress Design and Plastic Design 6/1/89”
- Bar joist design shall meet or exceed the
requirements of the Steel Joist Institute (SJI) “Standard
Specifications for Open Web Steel Joist H Series,” adopted
11/7/83.
- OSHA (Occupational Safety & Health
Administration) regulations shall be met or exceeded.
- Other codes specified by the customer, such as
“National Building Code” by BOCA, “Uniform Building Code
” by ICBS, or “Standard Building Code ” by SBCCA, shall be
met by the manufacturer.
- LOADS AND DEFLECTIONS
- Design shall meet the customer´s requirement for
live load.
- Structure shall be designed to withstand
horizontal forces as required by the seismic zone at the site of
installation.
- Stairs and landings shall be designed for a live
load of 100 psf.
- Deflection of all components under full live load
shall not exceed 1/300 of span.
- Special requirements for concentrated load (i.e.
racks, shelving, pallet trucks, etc.) shall be met by the
manufacturer when specified by the customer.
III. STRUCTURE
- COLUMNS
- Column spacing shall meet field conditions and
requirements of customer.
- Column size shall be a minimum of
5”x5”x3/16” square tube.
- Baseplates shall be a minimum size of 8” x 8”
x 1/2”, and anchored with four (4)1/2” dia. anchor bolts.
- STRUCTURAL STEEL SUPPORT MEMBERS AND BAR JOISTS
- All field connections shall be bolted.
- Wherever possible, beams shall rest on top of
columns.
- Bottom cord of bar joists shall be extended to
columns and attached .
- Bridging as per manufacturers design
specifications.
- STAIRS
- Stair shall be all-welded or bolt type
construction and produced with all structural steel members.
- All applicable codes specified by the customer
shall be met or exceeded.
- Stairs shall meet all design criteria specified
for the mezzanines (above).
- GUARD RAIL
- Railings shall be minimum 1 1/4” x 14 ga.
horizontal square tube or 1 1/4” structural welded round pipe
with schedule 40 thickness. (1 1/2” O.D.). All railings
rounded or square to have continuous top rail with smooth
transitions from one level to another.
- Intermediate rail spacing to meet applicable
codes.
- All railing locations to be provided with 4” x
1/8” structural kickplate.
- All applicable codes specified by the customer
shall be met or exceeded.
IV. MATERIALS
- STRUCTURAL STEEL BEAMS shall be hot rolled wide flange
and meet the requirements of ASTM Spec A36 “Standard Specification
for Structural Steel” (minimum yield strength of 36,000 pounds per
square inch:FY=36KSI). All steel members to be of domestic origin to
meet or exceed AISC Standards.
- BAR JOISTS shall meet the requirements of the Steel
Joist Institute referred to above and must be produced of structural
steel components of domestic origin.
- COLUMNS AND HANDRAILS shall be square tube and shall
meet the requirements of ASTM Spec. A500 titled “Cold Formed
Welded and Seamless Carbon Steel Structural Tubing in Rounds and
Shapes” (minimum yield strength of 45,000 psi. FY=3D 45 KSI).
- DECKS shall be constructed in one of the following
designs:
- BAR GRATING - 1” x 1/8” bearing bars welded on
1 3/16” centers with cross rods on 4” centers. Attach to
structure with saddle clips and tech screws. (2 per beam
crossed).
- PLYWOOD - 3/4” thick BC-grade, attached to
underlayment with minimum of 32 screws per full 4´ X 8´ sheet.
- DOUBLE LAYER WOOD - 1/2” BC-grade PLYWOOD
staggered on 1/2” Oriented Strand Board (OSB) attached to
underlayment with combined total of 32 or more screws per full 4´
X 8´ sheet.
- STEEL PLATE - Flat or diamond plate, 1/8” or
1/4” thick, meeting ASTM A36 and attached over underlayment
with a minimum of 20 mechanical fasteners per 32 sq. ft. area.
- OTHER DECKING as requested by the customer.
- DECK UNDERLAYMENT - B-deck for plywood and steel plate
shall be minimum 20 ga. (determined by design load) galvanized, or
high gloss white underside, wide ribbed steel decking with 1 1/2”
high corrugations, spaced 6” center to center, attached to
structure with minimum of two (2) tech screws per panel width for
every beam crossed.
- STRUCTURAL BOLTS shall conform to ASTM Spec A325
“High Strength Bolts for Structural Steel Connections”. Bolts
must be minimum of 3/4” diameter except for bar joist connections
which require no less than two (2) -1/2” diameter structural bolts
per joist. (ASTM A325) bolts to be of domestic origin to ensure
structural integrity.
V. PAINTING
- Structural steel beams and columns shall be cleaned
and sand blasted to remove all mill slag, rust and other debris to
assure proper adherence of paint to steel. Paint to be manufacturer´s
quick air dry high solids enamel in one of four standard colors.
Manufacturer to supply touch-up paint at the time of shipment. MSDS
sheets shall be provided detailing composition of paint.
- Guard Rail shall be cleaned and powder coated with
hi-gloss safety yellow.
VI. OTHER SPECIFICATIONS
- An inspection of the customer´s facility by the
manufacturer´s representative shall be conducted before
specifications are finalized.
- Manufacturer will adhere to local codes when requested
by the customer.
- Manufacturer to provide Performance and Payment bond
and must carry insurance coverage with a minimum 5 million umbrella
coverage for Product and General Liability with proof of Workmen´s
Compensation Insurance.
- Manufacturer must provide a Lifetime Warranty for all
workmanship, structural components and hardware.
-Back to top of page-
|